Groth 7618 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Groth 7618. Groth 7618 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
IOM-7618
Rev. D 12233
Ref. ID: 96056
©2011 Groth Corporation
Installation, Operation and Maintenance
Manual for Flame Arrester
Models 7618, 7628
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Manual for Flame Arrester

IOM-7618 Rev. D 12233 Ref. ID: 96056 ©2011 Groth Corporation Installation, Operation and Mainte

Strona 2

Page 10 of 16 V. MODEL NUMBER IDENTIFICATION The nameplate on the Flame Arrester contains the Model Number, Serial Number, set pressures and flow c

Strona 3

Page 11 of 16 APPENDIX A: Model 7618 Flame Arrester (2"-12") ITEM DESCRIPTION STANDARD MATERIALS OF CONSTRUCTION ALUMINUM CARBON

Strona 4 - based on

Page 12 of 16 APPENDIX B: Model 7618 End-of-Line Flame Arrester (2"-12") ITEM DESCRIPTION STANDARD MATERIALS OF CONSTRUCTION ALUMINUM

Strona 5

Page 13 of 16 APPENDIX C: Model 7618 Flame Arrester (14" and Larger) ITEM DESCRIPTION STANDARD MATERIALS OF CONSTRUCTION ALUM

Strona 6

Page 14 of 16 APPENDIX D: Model 7628 Flame Arrester (2"-12”) ITEM DESCRIPTION STANDARD MATERIALS OF CONSTRUCTION ALUMINUM CARBON STL 31

Strona 7

Page 15 of 16 APPENDIX E: Model 7628 Flame Arrester (14" and Larger) ITEM DESCRIPTION STANDARD MATERIALS OF CONSTRUCTION ALUMINUM CARBON

Strona 8

Page 16 of 16

Strona 9

Page 2 of 16 Table of Contents I. INTRODUCTION 3 II. INSPECTION AND INSTALLATION 4 1. TABLE 1 – FLAME ARRESTER MAWP 4 2. TABLE 2 – HOUSING AN

Strona 10

Page 3 of 16 I. INTRODUCTION Groth Corporation’s flame arresters are designed to inhibit flame propagation in gas piping systems and to protect low

Strona 11

Page 4 of 16 The MAWP is different from the approved pre-ignition pressure. Consult the factory for pre-ignition pressure limits for your installati

Strona 12

Page 5 of 16 The following guidelines should be observed at installation: WARNING: Groth Corporation's flame arresters have been tested by Fac

Strona 13

Page 6 of 16 WARNING: After installation, all connections must be inspected for vapor leakage. This may be accomplished by static pressure test, gas

Strona 14

Page 7 of 16 3. Loosen the housing nuts and remove only those studs necessary to withdraw the housing. Do not remove studs with spreader nuts. WARN

Strona 15

Page 8 of 16 5. On the remaining studs, loosen the housing nuts incrementally while advancing the spreader nuts to separate the bases. When the bas

Strona 16

Page 9 of 16 IV. SPARE PARTS Flame Bank Kits are available upon request. Kits include the flame arrester element and two non-asbestos gaskets. Ki